main article flowsheets articles
branches > beverage > beer
Download download article

pH measurement solution for wort boiling

Article index
 What is measured and for what reason:
 Why is it special:
 How can it be solved best:
pH measurement solution for wort boiling

What is measured and for what reason:

The right pH is essential the for a successful boiling process, because taste and color, but also hop isomerisation can be controlled better in specific pH ranges.

Why is it special:

The wort is sticky because of sugar and proteins. The temperature in the vessels is between 98 and 104°C. The vessels are cleaned with a CIP system.

How can it be solved best:

The pH system, build with an Endress+Hauser electrode, glass or ISFET, combined with an CPA 475 retractable process connection and a CPG 30 cleaning and calibration device fits perfect, because the sensor can be cleaned, even if the production is ongoing. The calibration system provides a stable quality and process control without manual work.

For more information: Endress+Hauser GmbH

forumReply to this article
All fields are required. Your personal information will not be displayed on our website. Hyfoma does not supply machines, but only refers to the companies that do. Most of the suppliers listed supply machines for the food industry, and do not produce food themselves.