main article articles
technology > utilities > cleaning, disinfecting > CIP - SIP
Download download article

Conductivity measurement in CIP plants

Article index
 What is measured and for what reason:
 Why is it special:
 How can it be solved best:
Conductivity measurement in CIP plants

What is measured and for what reason:

CIP processes are used in nearly all food production plants. They are build of a variable number of tanks with cleaning agents. Pumps and heat exchanger are providing flow and temperature. CIP plants are controlled by flow speed, temperature and concentration. The conductivity is used to detect the phase shift between two media, but also to control the concentration of the cleaning agents

Why is it special:

The process is mostly hot (around 90°C), caustic with standard concentration of about 2%, and acid below 0,8%. A fast response after the change of media results in a stable process. The conductivity changes with the temperature. For concentration measurement, the temperature needs to be compensated.

How can it be solved best:

The Endress+Hauser Smartec S 132/134 and CLS 52/54 conductivity sensors are equipped with a full Peek sensor. The temperature compensation can be made as well with an internal or external sensor. Fast response time is the result. Calculation tables for the concentration can be included in the transmitter.

For more information: Endress+Hauser GmbH

forumReply to this article
All fields are required. Your personal information will not be displayed on our website. Hyfoma does not supply machines, but only refers to the companies that do. Most of the suppliers listed supply machines for the food industry, and do not produce food themselves.

Name: Email:
Function: Company:
Send this reply to: