branches > zuivel > melk > sojamelk |
Dit artikel is nog niet beschikbaar in de door u gekozen taal
Milk measurement, flow verification with the Endress + Hauser Prosonic flow
Milk measurement, flow verification with the Endress + Hauser Prosonic flowWhat is measured and for what reason:
An old instrument needed to be verified within a concentrated milk plant.Why is it special:
For this measurement it is impossible to open the process. The inlet pipe was too short for most other instruments.How can it be solved best:
The Endress + Hauser Prosonic Flow ultrasonic flow meter is very fast and easy to install and to commission. The flow meter can be installed without interrupting the process. The sensor does not make contact with the process maintaining required sanitary conditions. The Prosonic can be dismounted and used on other applications. In addition to the verification of existing measurements, Prosonic Flow is an excellent tool for installation or commissioning support.Voor meer informatie: Endress+Hauser GmbH