 What is measured and for what reason:
 Why is it special:
 How can it be solved best:
Point Level switch for silo's with Endress + Hauser Soliphant

What is measured and for what reason:

In malt as well as in adjunct silos, the overspill protection is installed to save the silos from overspill. This is a safety aspect, but also ensures, that the silo area stays clean.

Why is it special:

The instrument may not be used for a long period, but a reliable signal is needed to prevent over spilling. The sensors must be able to work with dust, sticky product and bigger pieces of grain, without failing.

How can it be solved best:

The Endress + Hauser Soliphant, as well as a single rod, or fork version suits this application.

Para más información: Endress+Hauser GmbH

forumReply to this article
All fields are required. Your personal information will not be displayed on our website. Hyfoma does not supply machines, but only refers to the companies that do. Most of the suppliers listed supply machines for the food industry, and do not produce food themselves.